4. REFRIGERANT FLOW DIAGRAM
4-1. Refrigerant Flow Diagram
Indoor Unit SAP-K77RAX
SAP-K97RAX
SAP-K127RAX
Outdoor Unit SAP-C77RAX
SAP-C97RAX
SAP-C127RAX
Insulation of Refrigerant Tubing
Because capillary tubing is used in the outdoor unit, both the
wide and narrow tubes of this air conditioner become cold. To
prevent heat loss and wet floors due to dripping of
condensation, both tubes must be well insulated with a
proper insulation material. The thickness of the insulation
should be a min. 8 mm.
After a tube has been insulated,
never try to bend it into a narrow
curve because it can cause the tube
to break or crack.
Wide tube
Thickness:
Min. 8 mm
Insulation
Narrow tube
Thickness:
Min. 8 mm
IMPORTANT
CAUTION
Compressor
Accumulator
Wide tube
service
valve
Wide tube
*1
*1 O.D. 9.52 mm (3/8")
...
77, 97 class
O.D. 12.7 mm (1/2")
...
127 class
Narrow
tube
service
valve
Narrow tube
O.D.
6.35 mm
(1/4")
Heat exchanger
Heat exchanger
Cooling cycle
tinu roodtuOtinu roodnI
Capillary tube
19